Skip to main content

Diagram Standards

Version: 1.0.0 Status: Pilot — November 2026 Maintained by: Aviatrix Documentation Team
These standards apply to every architecture, topology, flow and before/after diagram on the documentation site. They do not apply to UI screenshots (see Style Guide). Diagrams are built with the diagram skill (.claude/skills/diagram/), which encodes these rules as code. Run /diagram to convert an existing diagram or to create a new one from a description.

Sources

The rules below come from three sources, in this order of precedence:
  1. Aviatrix Brand Guidelines 2026 (Marketing). Where the guide is explicit, it wins.
    • Location: Marketing SharePoint (Marketing2), Shared Documents > Active-Projects > Presentations > Aviatrix Brand Guidelines 2026.pptx
    • Edition used: October 2026 (read on 2026-11-10).
    • Slides used: Typography (9–10), Color Palette (11), Global Guidelines (16), Rules for Diagrams (18), Rules for PPT Design (19, colour values for dark grounds only) and Rules for Web (21).
    • Brand fonts: Marketing SharePoint, Brand Assets > Brand Fonts (Sora, Epilogue).
  2. The aviatrix-slides skill (v4.6.0), for choices the guide does not make: icon recolouring, line weights, label placement, spacing and the light-ground secondary tokens.
  3. Documentation-site rules, for what only matters on the docs site: light and dark mode, rendered size, SVG format and how diagrams are embedded in MDX.

When the brand guide changes

  1. Re-read the slides listed above and update this page.
  2. Bump the version (see Versioning) and add a changelog entry.
  3. Update the tokens in .claude/skills/diagram/scripts/diagramkit.py (THEMES, ROLES, KINDS) and the checks in lint.py.
  4. Update and rebuild the affected diagrams, then run lint.py.

Versioning

This standard has a semantic version (MAJOR.MINOR.PATCH, at the top of this page). Every diagram records the version it was built for, so you can tell which diagrams need work without opening them.
  • Each source script passes standard="x.y.z" to run(): the version the script was last written or reviewed against. The build stamps it into both SVGs as data-standard-version.
  • lint.py --versions lists every diagram with its version and how far behind it is.
The reference page How to Read Diagrams explains this visual language to readers, with legend sheets built by the diagram skill. Every MINOR or MAJOR change updates that page and its legend in the same change. The legend shows exactly the parts and icons that the diagrams use: every diagram records them, the legend is built from them, and a new part or icon gets a legend entry. lint.py enforces both. Pilot: the version stays at 1.0.0. While the standard is being refined in review, rule changes are made in place without a version bump, and every diagram is rebuilt against 1.0.0. Versioning starts when the documentation team declares the standard ready; from then on, bump the version in the same change that edits a rule: To update a diagram to a new version: adjust its source script to the changed rules, raise its standard= to the current version, rebuild, and check both previews.

Changelog

1.0.0 (pilot)

The initial release, refined during review from 2026-11-10 to 2026-11-12. The implementations below were made during the pilot, in order; they are all part of 1.0.0.

Colour carries meaning

Colour has two jobs in a diagram, and the rules differ per job. 1. Traffic and policy (strict). On paths, arrows, path labels and anything that says what happens to traffic, colours have fixed meanings: 2. Telling things apart (flexible). To distinguish functional parts of the network (VLANs, segments, routing domains, interface roles, regions, clouds), use the category palette, in this order:
  • Red and green are fine as categories here: the context (a labelled VLAN, a segment) makes clear they are not a threat or an allowed path. This is a documentation decision that relaxes the brand guide’s “red for threats only”; keep the strict meanings for traffic.
  • Category colour goes on elements (badges, swatches, panel outlines), never on paths. When a diagram also shows allowed or blocked traffic, avoid red and green as categories in that diagram, so the two vocabularies cannot be confused.
  • Every category colour is paired with its label (VLAN 100); colour is never the only signal.
  • Orange is never a category: it always means Aviatrix.
  • More than four categories: reuse the palette with distinct labels, or group them.
3. Cloud identity (outlines only). A container or panel that is explicitly in one cloud (a VPC or VNet on a cloud-specific page, a Direct Connect or ExpressRoute panel) gets that cloud’s colour as its outline:
  • Outlines only: never paths, fills or text. Generic constructs (“Transit”, “Private circuit”) stay gray.
  • The cloud is also named in the diagram (in the label, or by a device such as AWS Transit Gateway), so colour is never the only signal.
  • An Aviatrix-managed container keeps its orange outline (tone="aviatrix") even inside a cloud.
  • Alibaba Cloud’s orange is almost the same as Aviatrix orange. Always name Alibaba Cloud in the label of every Alibaba container, and never give an Aviatrix-managed construct inside it an orange outline without its label.
Keep colour that does a job. When converting a diagram, remove or neutralise a colour only if it carries no function. If the original uses colour to tell parts apart (VLANs, domains), keep that distinction with the category palette.
  • Orange is the only accent. Use one emphasis per idea.
  • No gradients, shadows, bevels or textures.
  • On light backgrounds, orange text uses the brand secondary dark orange #E24C01, as the Aviatrix website does. It is 3.99:1 on white, below the WCAG AA 4.5:1 for text, so keep orange text to short labels. Orange lines and fills stay #FA6B1E.

Paths and arrows

  • Solid orange: Aviatrix connections (tunnels, attachments, peerings) and traffic that Aviatrix steers or inspects.
  • Solid green: traffic that gets through: allowed by policy, or the preferred path.
  • Dashed red, ending in an arrowhead or an ✕: blocked, threat or ungoverned traffic. Dashed means “does not get through or is not governed”. Never dash any other line, including boundaries.
  • Solid gray: customer or cloud-provider routing outside Aviatrix (WAN, LAN, management, underlay).
  • Muted gray: a fallback path.
  • Connections end in round terminators, flows in arrowheads. A tunnel, an attachment or a peering is a connection with no direction: draw it with a small round terminator at each end, just outside the gateway it attaches to, so every connection reads as its own link. Traffic flows keep arrowheads.
  • Connections and traffic together. When a diagram shows both the overlay connections and the traffic that uses them (which next hop is preferred, which is the fallback), the connections stay orange with round terminators and the traffic takes the traffic colours, as arrows beside them: green for the allowed or preferred path, muted gray for a fallback. This keeps traffic from being read as a connection; it does not change what orange or green mean.
  • Keep connections separate: connections into the same gateway attach at different points (for example tunnels on the outer side, the peering on the inner side), each with its own terminators. Do not add bends just to change the side a connection attaches to.
  • Return traffic is its own, thinner arrow in the same colour, pointing back, when it takes a different path or needs to be shown separately (for example inspection on the way back). When both directions take the same path (symmetric routing), draw one line with arrowheads at both ends instead. This is a documentation decision that relaxes the brand guide’s “never a double-headed arrow” to keep such diagrams to one traffic line per connection.
  • Line weight follows the subject, so the subject reads first: when connections and traffic share a diagram, the connections are thinner and the traffic heavier. The weights are in the line-weight table under Element sizes.
  • Boundaries that are not containers (Availability Zones that span several VPCs) are a solid thin divider (d.line) with the names above the diagram. Never dash them: dashes mean blocked. Never use a double-headed arrow.
  • Complete flows. When the diagram shows the return of one flow, it shows the return of every flow of the same kind (east-west and egress alike). A return that shares a segment with another flow’s return reuses that arrow; it is not drawn twice.
  • Short labels at arrowheads use monospace caps: ALLOW, DENY.
  • Path labels name the path, not the interface. The interface badge already carries the interface and its role (eth0 · WAN, eth2 · MGMT), so the path label says only what the path is: DEFAULT ROUTE, EBGP, UNDERLAY BGP; never WAN DEFAULT ROUTE, MGMT DEFAULT ROUTE or LAN · EBGP.
  • Path labels sit on their own segment. A label that names a path (DEFAULT ROUTE, EBGP) is centred on the segment it names, just beside the line (about 12px), never crowded against an interface badge or a device: the badge names the interface, the label names the path between the badge and the next element.
  • Longer path labels go in a label card (path_label()): an opaque card of supporting text, all one size, that names the path, what it runs over and its qualifiers (Optional internet peering, backup with AS path prepend). On a long line, centre the card on it. On a short line (between two neighbouring gateways), hang the card just below it (about 14px), so the whole line stays visible: a card on a short line hides the relationship it labels. The card belongs to the path, not to the containers around it: keep it close to the line, narrow enough to sit between the nodes, and in the path’s colour (an orange outline for an Aviatrix path). It may sit across a container boundary; the boundary is hidden under it.
  • A label never moves the verdict. A path label sits where the thing it names happens. Inspection happens at the gateway, so it is named on the gateway (DCF, no SNAT) or in the legend (Inspected path), never on a segment after it, where it would credit the next element.
  • Add a legend when a diagram uses more than one path type.
  • A legend swatch is a small copy of its line, ends included: round terminators for a connection, an arrowhead for a flow, arrowheads at both ends for symmetric traffic. Colour alone does not separate a tunnel from the traffic that uses it; the ends do. A line type drawn with mixed ends (customer routing with and without arrowheads) gets a plain swatch. legend() takes the ends from the paths already drawn, so call it last.
  • Clearance: paths may cross box edges and other paths, but only at right angles. Where a path runs parallel to a box edge it keeps at least 24px from it; parallel paths keep at least 14px between them. An arrowhead ends at the edge of its node, never inside it, and a container edge never runs through a badge. The build prints a layout: warning for every violation; fix them all.

Shapes

  • Enforcement point (any Aviatrix gateway): an orange circle with the white Aviatrix icon centred. Never a plain block, a brand-library gateway icon, or the full wordmark.
  • Gateway groups and instances. Spoke and Transit Gateways form gateway groups: gateways that share one role. Why a group is one entity: depending on the supported features, a group holds anywhere from one gateway to n (more with horizontal scaling), and the gateways in it are peers with no leader, so a diagram that drew a fixed pair, a specific number or a role per gateway would be wrong for many readers and would go out of date as features change. A diagram therefore draws a gateway group as one entity, shown as two gateways, and draws each connection to it as two lines that stand for a connection to every gateway in the group. The reference page How to Read Diagrams explains this to readers. Draw them by what the diagram is about:
    1. Group (the default). One gateway with a second outline behind it (ghost=), labelled by type only (Transit Gateways), with no role subtext (see Gateway roles). Because the group holds two gateways, every connection to it (a tunnel, an attachment, a peering) is two lines, one to each gateway, drawn as a close pair 14px apart that nests at corners (connect_group()). A connection between two groups is also two lines. Traffic arrows are not connections: a flow through a group stays one arrow.
    2. Instances, when the diagram is about the individual gateways: their interfaces, tunnels or BGP sessions per gateway (ActiveMesh), failover between gateways, placement per Availability Zone, load sharing across firewalls. Draw each gateway separately, side by side and centred in its container, with its own connections, and name what tells them apart: the Availability Zone or the region, never a role.
    3. Other group sizes only where the page is about them, for example a page about configuring gateway groups: draw that many instances.
    4. A single gateway only where there is one, for example a single Edge Spoke Gateway. Never draw a group as a plain circle to simplify it.
    5. One choice per page. Every diagram on a page draws the same gateways the same way.
    A redundant pair of Edge Spoke Gateways is drawn as two instances.
  • Gateway roles. This is about gateway roles in the Aviatrix control plane: Spoke and Transit Gateways in a group are peers, and there is no leader. Never give them a role in a diagram, a caption or alt text: no Primary, HA, Backup, Standby, Active/Standby, Leader, and never master/slave. Call them gateways, or the gateways in the group. The build warns when a Spoke or Transit gateway label carries a role word.
    • Paths may have roles, because they describe routing, not gateways: a fallback path, a backup path with AS path prepend. Do not call a path “standby”; use “fallback”.
    • Exception: roles that a protocol or a documented product mode defines, on pages that document that mode. VRRP on Edge Spoke Gateways has a primary and a secondary (gateways and VIP addresses alike); do not mix in backup or standby for VRRP, and never use master, even though the protocol’s own state names do. The Edge Active-Active and Active-Standby modes keep their product names. Never master/slave.
    • UI labels are quoted exactly as the product shows them (an HA Gateway toggle in an older version), in procedures and screenshots, not as roles in diagrams.
  • Aviatrix management components (Controller, CoPilot): an orange-outlined box with the orange Aviatrix icon. They are not enforcement points, so they are not circles.
  • Workloads: rounded rectangles outlined in white (dark) or black (light). Allowed destinations get a green outline; threats are red dashed boxes.
  • Third-party devices (routers, firewalls, CSP gateways such as AWS Transit Gateway): gray-outlined boxes with a brand icon, or a vendor device icon (see Third-party devices, logos and FireNet).
  • Containers (cloud, region, VPC or VNet, AZ, subnet, site): panels with a thin gray outline. Nest at most two levels. An Aviatrix-managed or “after” container gets an orange outline.
  • Corners: 8–12px. Equal sizes for peer elements.
  • Icons: brand-library icons (.claude/skills/diagram/ICONS.md): monoline strokes with one orange accent. Vendor device icons and vendor logos follow the next section.
  • Before/after: problem on the left (or first), Aviatrix on the right (or second), in the same frame. Both diagrams use one geometry: every shared element keeps its position, and the space where the Aviatrix element goes is left empty in the “before”, so the “after” only adds and recolours.

Layout and alignment

  • Columns. Lay elements out on a few vertical columns. Every element sits centred on its column, and a column runs through all the containers it crosses (the Controller, the internet and the internet firewall share one column; the transit, the circuit, the WAN router, the edge gateway and the LAN router share another).
  • Centre in the container. An element alone in a container is centred in it; two gateways are placed symmetrically around the container’s centre. Never push an element against a container edge.
  • Overlays ride over the underlay. Tunnels that run over a circuit, the internet or a WAN router pass straight through that element rather than around it. Make the underlay element wide enough that the tunnels cross it near its edges (at least 24px inside them).
  • Underlay paths end at the underlay box. The underlay path that connects to a box with text (a private circuit) stops at the box’s edges instead of running across it, so the box’s title and text are centred in the whole box, with the tunnels crossing it on either side. Strictly the underlay runs through the circuit; ending the path at its edges keeps the text readable. The shared internet plane is the exception: every path that uses it crosses it.
  • Paint order: panels, then paths, then nodes. Containers, bands and panels are always below every path, so a path that passes through a container, a circuit or the internet is drawn across it, never hidden under it. Devices, gateways, badges and labels sit on top. diagramkit enforces this order whatever the order of the calls.
  • Labels stay clear of paths. No path crosses a container label, a device name or a path label. Put labels and text in the gaps between the paths that cross a panel.
  • Names stay close to their node. Put a gateway’s or device’s name on the side with the most free space (not the side its interfaces or paths use), and wrap a long side label onto two balanced lines (Edge Spoke / Gateway) so it starts right next to the node. gateway() wraps side labels wider than 180px automatically.
  • Container labels stay top-left. When a path enters a container near its label, wrap the label onto more lines (label_w=, for example EDGE / LOCATION) rather than moving it.
  • Infrastructure above, configuration below. Components and the traffic between them form the infrastructure band. Configuration (route tables, policies, snippets) goes in its own band below a solid divider labelled with what it holds (ROUTE TABLES). Each panel sits in the column of the element it configures, and its header names that owner (SPOKE 1 · PRIVATE SUBNET, TRANSIT GATEWAY). Never place a configuration panel between components or on a traffic path: it reads as a hop. Panels with rows Aviatrix adds or changes keep the orange outline and orange rows.
  • Outside means outside. Something that is not in any container (the internet) is drawn outside every container, with the paths crossing the container edge to reach it.
  • Interface badges carry the role (eth0 · WAN), so the lines need fewer separate labels.
  • Interface badges stay at the gateway. An interface badge sits on its line as close to the gateway as possible, the same distance for every interface in the diagram: 14px of visible line between the gateway circle and the badge, so the reader sees the line leave the gateway and the badge on it. When the line starts with a round terminator, the 14px start beyond the terminator. Never place an interface badge at the far end of its line, near the device it connects to: there it reads as that device’s. Lines that leave the same side of a gateway (eth0 and a tunnel) are spaced so the badge stays clear of the other line. interface() places the badge and port() gives the point where the line starts; the build flags eth badges placed by hand.

Third-party devices, logos and FireNet

Third-party products appear in many diagrams. Two kinds of vendor artwork are allowed, each for its own job: Rules
  • Cloud service icons are in the library. The official AWS and Azure service icons for networking, security, compute, containers, management, AI, storage and databases (979 icons, for example AWS Transit Gateway, Direct Connect, Azure Virtual WAN, ExpressRoute, Azure Firewall) are in assets/device-icons/ (names in the skill’s DEVICE-ICONS.md), with their provenance and terms in assets/logos/SOURCES.md. Use them for that cloud’s services on cloud-specific pages, unmodified and with the service name in text.
  • Generic pages stay generic. Architecture overviews, design patterns and anything that applies to several vendors use the brand-library icon (ngfw, router, nat-gateway …) and plain text names. A vendor’s artwork would suggest a preference or a requirement.
  • Vendor-specific pages may use vendor artwork, for example an implementation guide for Palo Alto VM-Series with FireNet, or an AWS-only design. Readers there already use that vendor; recognising it helps.
  • A logo never stands in for a device. Draw a FortiGate as a device with the FortiGate device icon (or, until that icon exists, the brand ngfw icon), not with the Fortinet logo.
  • Always keep the name as text. Artwork sits next to the product or vendor name, never alone, so the diagram stays readable, searchable and accessible.
  • Colour. Vendor logos and device icons keep their official colours: never recolour, crop or distort them (vendor trademark rules). Keep them small and away from coloured paths, so vendor colours are not read as diagram colours (orange for Aviatrix, red for threat). Use a vendor’s dark variant in dark mode when it provides one.
  • Official, unmodified artwork with recorded provenance. Logos come from the vendor itself (press kit, brand portal, trademark guidelines); device icons from the vendor’s official icon set. Never use community redraws for logos, and never redraw, crop or distort a file. Each file is listed in assets/logos/SOURCES.md with its source, date and the vendor’s brand guidance; the marks remain trademarks of their owners.
  • Missing artwork is registered. Logos and device icons we still need are listed in assets/logos/pending.json. The build (artwork pending:) and lint.py (ARTWORK notes) flag every diagram and diagram page that mentions a pending vendor or service, so conversions pick them up. Until the artwork arrives, use the brand icon and the name in text.
  • No vendor colours or logos inside Aviatrix shapes: the enforcement point and the Controller always use the Aviatrix icon.
FireNet
  • FireNet gateways are enforcement points: orange circles with the white Aviatrix icon.
  • The FireNet VPC or VNet is an Aviatrix-managed container: orange outline.
  • Third-party firewalls are devices: the vendor device icon on vendor-specific pages, otherwise the brand ngfw icon, with the product named in text (Palo Alto VM-Series, FortiGate VM). Several instances behind a load balancer are drawn as a short stack.
  • Paths: traffic Aviatrix steers to the firewall and back is solid orange (governed). The firewall’s verdict is green (allowed) or red dashed (denied), with ALLOW / DENY labels. Return traffic is the usual separate, thinner arrow, which also shows symmetric inspection.
  • Management, egress and other links are solid gray (customer or cloud-provider routing).

Text

  • Fonts: Sora for names of components, Epilogue for supporting text, Roboto Mono for panel labels, interfaces, routes and code. No other fonts.
  • At most three sizes per diagram. Nothing below 8pt as rendered on the page (see Size).
  • Container and panel labels: monospace caps, gray, letterspaced, with a middle-dot separator: SPOKE 1 VPC · 10.1.0.0/16, AZ · US-EAST-1A.
  • Interface names and code keep their case: eth0, 10.1.0.0/16.
  • Use product names exactly as in the doc style guide: Spoke Gateway, Transit Gateway, Edge Spoke Gateway, Distributed Cloud Firewall (DCF).
  • No titles, takeaway lines, notes or callout boxes inside the diagram. Text moves out of the image:
    • A title becomes a bold line directly above the <Frame> (for example **Before: no Aviatrix, all traffic uninspected**).
    • Comments (notes, callouts, footers, takeaways) become the <Frame> caption below the image. Keep their facts, rewrite them as plain sentences, and drop marketing or competitive claims.
    • Facts the page text already states in full can be left out of the caption.

Content

  • Show the real mechanism: the actual topology, paths and route changes, not an abstraction.
  • One thing, one symbol. A network or service that exists once (the internet, a circuit, a transit) is drawn once, and every path that uses it crosses that one element. Two internet clouds for the same internet are a difference without a distinction. The build warns when the internet is drawn more than once.
  • Every word earns its place. A secondary line adds information the name does not carry (Internet firewall / or router adds; Internet / Public internet does not). The build warns when a subtext repeats its name.
  • Repeating patterns stay readable. To show that a pattern repeats (more VLANs, more spokes), repeat its structure in muted form (the labels without the values) rather than an ellipsis.
  • Place shared things where they really live: something that spans both members of a pair (a VLAN, a VRRP virtual IP, a shared subnet) is drawn across both, never next to one of them.
  • When converting an existing diagram, keep its topology and every technical fact. Restyle it; do not simplify it. Record anything you drop in the source script header.
  • A path’s qualifiers stay on the diagram. Whether a link is optional, what it runs over (the internet, a private circuit), that it is a backup, and the setting that changes its role (AS path prepend) are part of the topology, not commentary: label the path with them. The caption may explain more (the default behaviour), but never instead of the label.
  • Never invent technical details. Illustrative names, CIDRs and regions are fine; say so in the source script header.
  • Balance accuracy against simplicity: leave out detail that does not serve the reader’s task.

Light and dark mode

Every diagram ships as two SVG files with identical layout and meaning: The background is transparent in both variants so diagrams never show as a light box on a dark page or a dark box on a light page. The dark values are the brand guide’s diagram canvas tokens; the light values are the guide’s light-ground palette.

Element sizes

One size per element type, in every diagram (canvas px; the page shows about two thirds of this): Line weights keep one hierarchy, so the subject reads first and every outline stays visible at page size: Never draw a container outline as heavy as a path: a coloured outline (AWS amber) would read as a connection.

Size

  • Canvas width: 1000px by default. Height as needed.
  • Mintlify scales the SVG down to the content column (designed for 680px). At a 1000px canvas, the smallest text is 16px, which renders at about 8pt.
  • A wider canvas needs proportionally larger text; lint.py enforces the floor.

Files and format

  • Self-contained SVG: fonts are subset and embedded, no external references, no raster images, no scripts. Text stays selectable.
  • Files: images/<section>/<name>.svg and images/<section>/<name>-dark.svg (kebab-case).
  • When a converted diagram replaces an image with a different file name or format (for example a PNG), delete the old image in the same change once no page references it, so the git diff shows the old and the new side by side. Update scripts/image-dedup-baseline.json if the deleted file was in a baselined duplicate group (python3 scripts/check_image_duplicates.py --write-baseline).
  • Source: every diagram has a Python source script in diagrams/, at the same path as its image, with a header that records the mode (convert or create), the input, the sources, and assumptions to verify, and a standard="x.y.z" argument to run() (see Versioning). Edit the script and rebuild; never edit the SVG by hand.
  • Inventory. diagrams/INVENTORY.md records every diagram with the standard version it is built to (legacy until it is converted), its last change and its pages, and lists the diagrams no page uses. It is generated and checked by the diagram skill’s scripts; keep it current with every diagram change.

Embedding in MDX

Embed both variants inside one <Frame>. Mintlify shows the variant that matches the reader’s theme.
  • Use the same descriptive alt text on both images: describe what the diagram shows, not that it is a diagram.
  • Put the diagram’s title, if it has one, in bold on the line directly above the <Frame>. (Mintlify’s <Frame> does not render a title attribute.)
  • Use the <Frame> caption for the takeaway and any comments the diagram carried (see Text).
  • lint.py checks the pair, the classes and the alt text.
  • assets/css/custom.css hides Mintlify’s decorative grid pattern in diagram frames (it would show through the transparent SVG background) and adds space between consecutive frames, such as a before/after pair. It recognises a diagram frame by the dark:hidden image class, so keep the embedding exactly as above.

Checklist

  • Traffic colours keep their meaning (orange Aviatrix, green allowed, red threat or blocked); categories use the category palette on elements, with labels.
  • Only red paths are dashed; return traffic is a separate, thinner arrow, shown for every flow of a kind or for none.
  • Configuration (route tables, policies) sits in its own band below the components, aligned with its owner.
  • Path labels name what happens on that segment; verdicts sit on the element that makes them.
  • Path labels are centred on their segment, close to the line and clear of badges.
  • Interface badges sit at their gateway, the same short distance from it, with a piece of line visible.
  • Every qualifier of a path in the original (optional, what it runs over, backup, conditional) is still on the diagram.
  • Underlay boxes (a private circuit): the tunnels cross them, the underlay path ends at their edges, the text is centred.
  • Gateways are orange circles with the white Aviatrix icon.
  • No roles for Spoke or Transit Gateways (Primary, HA, Backup, Standby, Leader, master/slave) in the diagram, caption or alt text.
  • Spoke and Transit Gateways are drawn as a group (two gateways shown as one, two lines to it) unless the diagram is about the individual gateways; the same way on every diagram of the page.
  • Sora, Epilogue and Roboto Mono only; at most three sizes; nothing below 8pt rendered.
  • Light and dark variants exist, both checked on their page colour.
  • Source script in diagrams/ with a complete header and standard= set to the current version.
  • Both variants embedded in one <Frame>, with alt text and a caption.
  • New icons or parts are in the diagram legend; a rule change updated How to Read Diagrams.
  • lint.py passes.